Magnetic fixed gas detector sensitivity setting

09/08 2026

Magnetic fixed gas detector is used to continuously monitor specific gases in industrial and commercial environments. The equipment is equipped with liquid crystal display screen and magnetic operation interface, which can display gas concentration information in real time and allow users to enter relevant operating parameters for setting.

Sensitivity setting is one of the parameters that may affect the detection response of fixed gas detector. Correct parameter configuration is helpful to maintain stable monitoring performance and ensure that the detector can respond appropriately to the change of target gas concentration.

This paper will introduce the basic operation flow of sensitivity setting of magnetic fixed gas detector and explain the important matters needing attention in the adjustment process.

Magnetic fixed gas detector sensitivity setting

What is the sensitivity setting of gas detector?

Sensitivity is mainly used to describe the response ability of gas detection system to the change of target gas concentration.

Different sensor technologies have different response characteristics. Electrochemical sensors, catalytic combustion sensors, infrared sensors and other types of sensors may have different detection principles and response characteristics.

Therefore, before adjusting the sensitivity parameters, the detector model, sensor type, target gas, detection range and practical application environment should be considered comprehensively.

Why is sensitivity setting important?

The sensitivity of gas detector will affect the response of the instrument to the change of gas concentration.

If the parameter setting is unreasonable, it may affect the measurement stability and the expected response effect of the detector. The correctly configured detector is helpful to maintain stable gas monitoring during normal operation.

Reasonable parameter setting can help:

  • Maintain stable gas concentration monitoring.
  • Improve the response ability to the change of gas concentration.
  • Reduce unnecessary fluctuation of displayed values.
  • Support reliable alarm function.
  • Adjust the detection parameters according to the actual application requirements.
  • Maintain stable performance during long-term operation.

It should be noted that sensitivity setting cannot replace gas calibration. Zero calibration and range calibration belong to different operations, which are used to establish the benchmark of the detector and adjust the detection response through the standard gas with known concentration.

How to set the sensitivity of magnetic fixed gas detector?

The specific operation mode depends on the model of the detector and its control interface. A typical magnetic fixed gas detector may enter the parameter setting menu through a magnetic operating pen or magnetic button.

1. Enter the parameter setting menu.

Ensure that the tester is powered on normally and in normal working condition.

Use the magnetic operation tool or the corresponding control key to enter the parameter setting menu.

Some models may need to enter a password or obtain administrator rights before entering the important parameter setting function.

2. Find the sensitivity setting

After entering the parameter menu, find the setting options related to sensitivity.

The parameter names and menu numbers of different types of detectors may be different. Therefore, before making adjustments, it is recommended to check the instruction manual of the corresponding product.

3. Adjust the sensitivity parameters

Adjust the sensitivity according to the parameter range recommended by the manufacturer and the actual application requirements.

Do not increase or decrease the sensitivity value at will. Excessive adjustment of parameters may affect the measurement stability or the normal response characteristics of the detector.

4. Confirm and save the settings

After selecting the required parameter values, confirm the settings and save the parameters.

After saving, some detectors may automatically return to the normal gas concentration display interface.

5. Check the detector

After completing the sensitivity adjustment, observe the LCD screen to check whether the gas concentration reading is stable.

If necessary, check the alarm indicator and other related functions of the tester.

If the detector shows abnormal reading after adjustment, check the sensor, installation environment, wiring and calibration status before continuing to modify the parameters.

Magnetic attraction operation and parameter setting

One of the characteristics of some magnetic fixed gas detectors is that they can perform important functions without opening the equipment shell.

For example, some fixed gas detectors use a magnetic operating pen, and the menu function is triggered through the front panel of the equipment, thus completing the relevant parameter setting. This design is very practical for industrial environments that need to keep the equipment enclosure sealed.

The magnetic operation mode can reduce the need to open the equipment shell and provide a more convenient operation mode for daily parameter setting and maintenance.

What is the difference between sensitivity setting and gas calibration?

There is a certain relationship between sensitivity setting and gas calibration, but they are not the same operation.

Sensitivity setting is mainly to configure the internal response parameters of the detector.

Zero calibration is to establish the reference value of the detector under appropriate zero reference conditions.

Range calibration is to use the standard gas with known concentration to adjust the measurement response of the detector.

Therefore, modifying the sensitivity parameter does not mean that the detector has completed the gas calibration.

What factors may affect the gas detection performance?

Many factors may affect the actual response performance of the fixed gas detector.

Sensor type

Different sensors adopt different detection principles and have different response characteristics.

Therefore, the sensitivity parameters and calibration requirements should match the actually installed sensors.

Target gas

The detector shall be equipped with a sensor suitable for the target gas.

For example, methane, carbon monoxide, hydrogen sulfide, oxygen and other gases need to use corresponding sensor technology and detection range.

Temperature and humidity

Changes in temperature and humidity may affect the working performance of the sensor.

When the detector is installed outdoors or in a harsh industrial environment, the actual environmental conditions should be fully considered.

Installation position

The installation position will affect the speed at which the gas reaches the sensor.

The installation position of the detector should be reasonably selected according to the density, diffusion characteristics, potential leakage sources, ventilation conditions and practical application requirements of the target gas.

Matters needing attention in sensitivity setting of magnetic fixed gas detector

When adjusting the sensitivity of magnetic fixed gas detector, the following items should be paid attention to:

  • Follow the operating instructions provided by the manufacturer.
  • Confirm the sensor type and target gas before modifying the parameters.
  • Don’t modify the sensitivity without knowing the parameter function.
  • Use the parameter range recommended by the manufacturer.
  • Perform gas calibration according to the manufacturer’s requirements.
  • Check the display reading of the detector after adjustment.
  • Check the alarm parameters if necessary.
  • Record the modification of important parameters.
  • Check and maintain the detector regularly.
  • If the detector has abnormal readings, you should contact professional and technical personnel for inspection.

When is it necessary to calibrate the fixed gas detector?

Periodic calibration is an important part of the maintenance of fixed gas detector. The specific calibration period depends on sensor technology, application environment, operating conditions and manufacturer’s suggestions.

Re-calibration may also be required after sensor replacement, obvious measurement drift is found, or maintenance work that may affect the detection system is carried out.

When carrying out range calibration, standard gas with known concentration and matching with detector and sensor should be used.