This intrinsically safe combustible gas detector is specifically designed for on-the-go industrial site inspections. It enables rapid detection, real-time alarms, and data traceability of combustible gases, making it an essential safety tool for workers. Features include high-precision detection, a multi-level alarm system, portability, and long battery life.

  • SIL 2 Certification
  • CE Certification
  • Ex Certification
  • PA Certification
  • FC Certification
  • High precision

  • Global Shipping

  • Customized

  • 24*7 support

  • OEM/ODM

  • Features
  • Parameters
  • Accessories
  • Gases and Ranges

The HRP-B1000-A is a portable combustible gas detector specifically designed for emergency detection of certain combustible gases. Designed for on-site personnel, it provides rapid early warning of combustible gas leaks. It can accurately detect combustible gases (such as methane CH4, acetylene C2H2, hydrogen H2, propane C3H8, etc.). Widely used in mines, chemical plants, electroplating plants, wastewater treatment plants, gas system maintenance, and confined space operations, it is an essential tool for daily inspections, equipment maintenance, and emergency troubleshooting of combustible gas leaks, and a crucial means of ensuring personnel safety.

Single gas detector usually adopts "one-button" design, which can measure immediately when it is turned on, without complicated menu settings.
1.Lower the training threshold: For grass-roots workers with high mobility, there is no need for complicated equipment operation training.
2.Reduce misoperation: there are no redundant keys and interference information, the display screen shows the current concentration intuitively, the alarm logic is simple and direct, and it can rely on instinct to respond correctly in case of emergency panic.

 

  • Portable-gas-leak-detector-HRP-BJ1000-frontage
  • Portable-gas-leak-detector-HRP-BJ1000-Real-shot
  • Portable-gas-leak-detector-HRP-BJ1000-Real-shot-1

Portable single gas detector is a compact and high-precision safety equipment, which is used to continuously monitor a single specific gas in industrial environment. It can detect toxic gas, anoxic environment and combustible gas in real time, and is widely used in oil and gas, petrochemical, mining, environmental protection and confined space operation scenes to ensure the safety of operators.

The equipment is equipped with high-performance sensor, solid protective shell and multiple alarm systems, which can provide reliable gas monitoring anytime and anywhere.


Product core characteristics

Real-time continuous gas concentration monitoring
High precision electrochemical, catalytic combustion, PID or NDIR sensors
Triple alarm of sound, light and vibration
Small and light, support waist clip to wear.
Long battery life rechargeable lithium battery
Data recording and historical event storage (some models)
Industrial protection grade: IP66/IP67
Intrinsically safe explosion-proof design


principle of operation

The equipment operates in a diffusion sampling mode:

Gas enters the sensor by natural diffusion.
The sensor detects the concentration of the target gas.
The signal is converted into an electrical signal for output.
MCU processes and calculates the data.
The screen displays the gas concentration in real time.
When the threshold is exceeded, an alarm is triggered.

Example:
"EX 0%LEL" means the combustible gas monitoring mode with the lower explosion limit (LEL) as the unit.


Support detection of gas types

Depending on the sensor configuration, the following gases can be detected:

Oxygen (O₂)—-Electrochemical Sensor
Carbon monoxide (co)-electrochemical sensor
Hydrogen Sulfide (HS)-Electrochemical Sensor
Ammonia (NH₃)—-Electrochemical Sensor
Chlorine (Cl₂)—-Electrochemical Sensor
VOC Volatile Organic Compounds-—PID Sensor
Methane (CH₄)—-catalytic combustion or infrared sensor
Carbon dioxide (CO)-NDIR sensor


Application industry

Oil and gas industry

Pipeline inspection, drilling platform, LNG station and storage tank area

Petrochemical industry

Refineries, chemical plants, fertilizer plants

Environmental protection industry

Sewage treatment plant, landfill, underground pipe gallery

Mine and tunnel engineering

Coal mine, metal mine and underground construction

Emergency rescue

Fire rescue, gas leakage treatment, confined space rescue


Product advantage

1. Small and portable design

Equipped with waist clip, it can be worn for a long time and is suitable for inspection personnel.

2. 24 hours real-time monitoring

Continuously detect the concentration of ambient gas to ensure all-day safety.

3. Multiple alarm system

audible alarm
LED light alarm
Vibration alarm
Even in high noise environment, it can remind you in time.

4. High precision sensor

Fast response, strong stability, T90 ≤ 30 seconds.

5. Long battery life

Adopt rechargeable lithium battery, which can support long-term industrial use.

6. Data storage function (optional)

Record alarm events, gas concentration and historical data for safety analysis.

7. Industrial protection

IP66/IP67 protection grade, dustproof, waterproof and impact-resistant.


Why choose our portable single gas detector?

The equipment is specially designed for high-risk industrial environment, with high-precision detection capability, rapid alarm mechanism and durable structure, which can effectively reduce the safety risks caused by gas leakage and is widely used in the global industrial safety field.


Frequently asked questions (FAQ)

Q1: What gases can be detected?
According to the configuration, gases such as O, CO, HS, CH, VOC, NH and Cl can be detected.

Q2: Is it suitable for confined space operation?
Applicable, widely used for safety monitoring before entering confined space and during operation.

Q3: How long does the battery last?
Depending on the model, it can usually support the use time ranging from several days to several months.


Improving work safety with real-time gas monitoring

Portable single gas detector is an indispensable safety equipment in industrial operation. With high-precision detection ability, reliable alarm system and solid structural design, it provides all-weather security for petroleum, chemical, mining and environmental protection industries.

Single Gas Detec

  • Sampling method: natural diffusion
  • Detection Range:PPM, %LEL, %VOL, mg/m³
  • Accuracy: ≦ 5% FS. (EX/CO/O2/H2S≤3%FS)
  • Response time: T<60s (EX/CO/O2/H2S≤30S)
  • Working temperature: Combustible gas: -20℃~70℃
  • Toxic and O2: -10℃~55℃"
  • Working humidity: <95%RH (no condensation)
  • Operating voltage: DC3.7V Li battery 2000mAh
  • Battery Runtime: >8H
  • Alarm method: Audible, visual, and vibration alarm
  • Ingress protection: IP66
  • Explosion-Proof Rating: EX db IIC T6 Gb
  • Dimensions: 145*70*35mm
  • Weight:250g
Portable-gas-leak-detector-HRP-BJ1000-frontage
  • Usb-cable

Usb cable(Standard):

This Micro USB cable features thickened copper cores and high-density nylon braiding, offering excellent resistance to bending and abrasion for long-lasting durability.

  • Portable-Calibrator-Calibration-Gas-Cylinder

Portable Calibrator Calibration Gas Cylinder(Optional):

The high-precision standard gas supply device designed by portable gas detector is used for periodic calibration, zero correction and range verification of sensors in the field or laboratory to ensure the accuracy and reliability of long-term operation data of testing equipment.

  • Calibration-Hood

Calibration Hood(Standard):

The compact calibration cover designed by portable hand-held gas detector is used to quickly and accurately complete the zero calibration and range calibration of sensors on the equipment site. It is small, light and precise in structure, which ensures that the standard gas can cover the sensor probe efficiently and avoid the interference of ambient airflow. It is an indispensable professional accessory for daily maintenance and compliance testing.

  • Air-Sampling-Probe

Air Sampling Probe(Optional):

The high-precision and long-distance gas sampling extension tool designed by portable hand-held gas detector is used to safely and stably extend the probe into narrow space, high place, deep well, pipeline or dangerous area for remote gas detection, which greatly improves the operation safety and detection coverage.Typically used with sampling tubes.

  • Portable-hand-held-gas-detector-charger

Portable Hand-held Gas Detector Charger(Standard):

The high compatibility, safe and reliable charging solution designed by portable hand-held gas detector includes a standard two-pin plug power adapter and a USB-A to Micro-USB/Type-C data cable (matched according to the equipment interface), which ensures that the equipment can quickly recover power after field inspection, factory duty or emergency tasks, and ensures continuous and stable operation.

  • Extended-Sampling-Tube

Extended Sampling Tube(Optional):

The portable hand-held or pumping gas detector is designed with a high flexibility and corrosion resistance to extend the sampling catheter, which is used to extend the gas inlet of the equipment to the detection points that are difficult to directly contact, such as the depth of the pipeline, the equipment interlayer, the high vent, the inside of the closed container, etc., so as to realize "remote accurate sampling" and greatly improve the detection coverage and operation safety.

  • Water-vapor-and-dust-filter

Water Vapor and Dust Filter(Optional):

Blocks solid particles from entering the detector's gas path, preventing blockage and avoiding particle adhesion to the sensor surface, which could cause sensor poisoning, decreased sensitivity, slowed response, or even permanent failure. It also avoids physical interference from dust, ensuring the sensor only contacts the measured gas, thus guaranteeing measurement accuracy.

Name Chemical Formula Lower Explosive Limit(Volume Fraction)in Air%VOL|Lower Limit Serial No Name Chemical Formula Lower Explosive Limit(Volume Fraction)in Air%VOL|Lower Limit
Ethane C₂H₆ 3.0  49  Cyclohexane CH₂ (CH₂)₄CH₂ 1.2 
Ethanol C₂H₅OH 3.4  50  Cyclohexanol CH₂ (CH₂)₃CHOHCH₂ 1.2 
Ethylene C₂H₄ 2.8  51  Cyclohexanone CH₂ (CH₂)₃COCH₂ 2.8 
Hydrogen H₂ 4.0  52  Cyclopropane CH₂CH₂CH₂ 2.4 
Methane CH₄ 5.0  53  Decane C₁₀H₁8 0.7 
Methanol CH₃OH 5.5  54  Cyclohexene CH₂ (CH₂)₃CHCHCH₂ 1.2 
Acetylene C₂H₂ 2.5  55  Diacetone Alcohol (CH₃)₂COHCH₂COCH₃ 1.8 
Propanol C₃H₇OH 2.5  56  Di-n-butyl Ether C₄H₉OC₄H₉ 0.9 
Propane C₃H₈ 2.2  57  Dichlorobenzene (C₆H₄)Cl₂ 2.2 
10  Propylene C₃H₆ 2.4  58  Diethylamine (C₂H₅)₂NH 1.7 
11  Toluene C₆H₅CH₃ 1.2  59  Dimethylamine (CH₃)₂NH 2.8 
12  Xylene C₆H₄ (CH₃)₂ 1.0  60  Dimethylaniline (CH₃)₂C₆H₃NH₂ 1.2 
13  Dichloromethane C₂H₄Cl₂ 5.6  61  Dicyclohexylamine (CH₂)₄O₂ 1.9 
14  Dichloroethylene C₂H₂Cl₂ 6.5  62  Ethylene Oxide OCH₂CH₂CH₂ 1.9 
15  Dichloropropane C₃H₆Cl₂ 3.4  63  Diethyl Ether C₂H₅OC₂H₅ 1.8 
16  Diethyl Ether C₂H₅OC₂H₅ 1.7  64  Ethyl Acetate CH₃COOC₂H₅ 2.1 
17  Dimethyl Ether CH₃OCH₃ 3.0  65  Ethyl Acrylate CH₂CHCO₂C₂H₅ 1.7 
18  Formaldehyde CH₂OCH 4.0  66  Styrene C₆H₅C₂H₃ 1.0 
19  Acetic Acid CH₃COOH 4.0  67  Ethylene Oxide CH₂CH₂O 2.6 
20  Acetone CH₃COCH₃ 2.3  68  Ethanethiol C₂H₅SH 2.3 
21  Acetyl Chloride (CH₃CO)₂CH₂ 1.7  69  Ethyl Mercaptan C₂H₅SCH₃ 2.0 
22  Chloroform CH₃COCl 5.0  70  Methyl Ethyl Ketone C₃H₇COCH₃ 1.8 
23  Acrylonitrile CH₂CHCN 2.8  71  Ethylamine C₂H₅NH₂ 3.5 
24  Allyl Chloride CH₂CHCH₂Cl 3.2  72  Gasoline 0.9 
25  Methylacetylene CH₃CCH 1.7  73  Kerosene 0.7 
26  Amyl Acetate CH₃CO₂C₅H₁1 1.0  74  Turpentine 1.8 
27  Aniline C₆H₅NH₂ 1.2  75  Nitrobenzene C₆H₅NO₂ 1.8 
28  Benzene C₆H₆ 1.2  76  Nitromethane CH₃NO₂ 7.1 
29  Benzaldehyde C₆H₅CHO 1.4  77  Phenol C₆H₅OH 1.3 
30  Benzyl Chloride C₆H₅CH₂Cl 1.1  78  Phenylacetylene C₆H₅C₂H 1.1 
31  Bromobenzene C₆H₅CH₂Br 2.5  79  Ethylbenzene C₆H₄C₂H₅ 1.0 
32  Bromoethane CH₃CH₂Br 6.7  80  Methyl Formate HCOOC₂H₅ 2.7 
33  Butadiene CH₂CHCHCH₂ 2.0  81  p-Dioxane C₄H₈O₂ 2.0 
34  Butane C₄H₁0 1.9  82  Isobutane i-C₄H₁0 1.8 
35  Butanol C₄H₉OH 1.8  83  Naphthalene C₁₀H₈ 1.9 
36  Butylene C₄H₈ 1.6  84  Nonane CH₃ (CH₂)₇CH₃ 0.7 
37  Butyraldehyde C₃H₇CHO 1.4  85  Nonanol CH₃ (CH₂)₇CH₂OH 0.8 
38  Butyl Butyrate C₃H₇COOC₄H₉ 1.2  86  Valeraldehyde C₆H₁₀0 1.2 
39  Butyl Methyl Ketone C₄H₉COCH₃ 1.2  87  Pentane C₅H₁2 1.4 
40  Carbon Disulfide CS₂ 1.0  88  Pentanol C₅H₁₁OH 1.2 
41  Chlorobenzene C₆H₅Cl 1.3  89  Propylamine C₃H₇NH₂ 2.0 
42  Chlorobutane C₄H₉CH₂Cl 1.8  90  Propyl Methyl Ketone C₄H₉COCH₃ 1.5 
43  Chloroethane CH₃CH₂Cl 3.8  91  Pyridine C₅H₅N 1.7 
44  Chloroethylene CH₂CHCl 3.8  92  Tetrahydrofuran C₄H₈O 2.0 
45  Chloromethane CH₃Cl 8.1  93  Tetrahydrofurfuryl C₅H₁₀O₂ 1.5 
46  2-Chloropropane CH₃CHCICH₃ 2.6  94  Triethylamine (C₂H₅)₃N 1.2 
47  Cresol C₆H₄OH 1.1  95  Trimethylamine (CH₃)₃N 2.0 
48  Cyclobutane CH₂CH₂CH₂CH₂ 1.8  96  Trioxane (CH₂O)₃ 3.0 

Send Message